AQ2 Customer Support Manual The SEAL Analytical AQ2 Customer Support Manual is designed to provide our customers with the Information and Operational / Maintenance Checklists needed to operate the AQ2 at full capacity. There are 9 different sections or tabs in the Customer Support Manual.
Maintenance Checklists The first 3 tabs are set up to organize the Operational / Maintenance Checklists. • Daily / Weekly Checklist • Monthly Maintenance Checklist • 6 Month Maintenance Checklist
Annual Maintenance The 4th tab is for the Annual Maintenance functions: • 12 Month Maintenance Training • SEAL Analytical Service Contract Information • File your 12 Month Required Maintenance Checklist provided during your yearly Preventative Maintenance Visit.
AQ2 "How To" Tip Sheets These tip sheets (filed in tab #5) provide the most up-to-date information and advice on "How To" get things done. They are designed to remind the Maintenance trained operator of the steps needed to replace the wear parts on the AQ2. • Change the Lamp - How to change and what to adjust • Peristaltic Pumps - How to change pump tubes, lube the pump rollers and check that pumps are pumping at the correct volume • Change the Syringe - The Easy way... • More to come
AQ2 Methods Listing + The methods you use The 6th tab is used to file the actual SEAL AQ2 methods you use every day. In addition we have the latest AQ2 Method Listing complete with the pertinent USEPA / Standard Methods Equivalence. Similar listings can be provided to our world wide customers based upon local regulations.
Standard Testing Measuring Diagnostic Method The 7th tab is devoted to Standard Testing Methods. The SEAL AQ2 is simple to operate and it is quite simple to test that it is operating correctly. The Measuring Diagnostics test is designed to detect problems: • Dirty Cuvette - The most common problem, easily remedied by the "Extra Wash" function. • Hydraulic Problems - Worn pump tubes, pumps need cleaning and Lubrication - Monthly Maintenance Checklist items • Electronic Noise
Standard Testing Dye Calibration and Precision The Dye Calibration Testing (7th tab) is used to check the operation of the syringe, optical filter and the hydraulic system of the AQ2. By taking a solution of a known concentration and asking the AQ2 to create a calibration curve, we can see if the AQ2 is operating correctly. This is a very useful trouble shooting procedure
Technical Tips & Troubleshooting • Cadmium Coil Regeneration • Error Codes • Import a Schedule • Ammonia in Sodium Potassium Tartrate • Cleaning with Bleach • Control Abbreviations and Sample Types • Reagent Shelf Life • Calculation Spike Recovery • Technical Tip - Sample Addition • AQ2 Troubleshooting • Filters List by Method
Please call us to get yours !
|